Mark II Extreme Duty Air Amplifier
|
The Mark II™ Extreme Duty Air Amplifier was
developed by Enertechnix for continuous duty in hot, dirty
environments.
In comparison to other commercial air intensifiers, which
are typically unable to perform continuously in hot, dirty
environments for more than 30 days without failure, the Mark
II averages six months of continuous duty between standard
maintenance cycles.
The Mark II amplification factor is 6.25:1. The regulator is
used to set the output pressure between 250 and 625 psi
depending on application requirements. The Mark II system
consists of a pneumatic piston assembly driven by magnetic
sensors and a heavy-duty air control valve. Low-pressure
filtered air (40-100 psi) enters the regulator and is
diverted to the low-pressure cylinder by the air control
valve.